SENA Parani-MSP100 User Manual
Page 33
33
4.2.1. Parani-MSP100 Configuration
•
Basic Setting
(1) Bluetooth name: For user Parani-MSP100 name revision
(2) Maximum Connection: For configuring the maximum number of Bluetooth devices connectable
to Parani-MSP100.
Default maximum is 7.
(3) Discoverable: When checked, Parani-MSP100 is in INQUIRY mode, discovering in-range
Bluetooth devices.
(4) Connectable: When checked, Parani-MSP100 is in PAGE mode, connecting to Bluetooth
devices.
(5) Pairable: For Pairing mode enable/disable.
When in need of high security, set Pairable option
to UNCHECKED, enabling High Security.
When this option is NOT checked, other Bluetooth
devices, except those previously connected to Parani-MSP100, cannot connect to Parani-MSP100,
even via PIN code.
(6) Control port: For control port number entry.
Default value is 2525.
•
Buffering
(1) Buffering: For Buffering function enable/disable
* Firstly set Header and Trailer, secondly turn on Buffering option.
(2) Header: For buffer frame header entry.
Enter alphabet or HexaCode.
(3) Trailer: For buffer frame trailer entry.
Enter alphabet or HexaCode.
•
Security