For Host connect retry, if failed.
Retry frequency is set in the preceding function.
•
Try to Connect to Server every [] ms
When Parani-MSP100 fails to open a data channel connecting to Host, enter the connection
retry frequency. Entering 0 [zero] obtains retry abort.
C) Vertex Mode
Parani-MSP100 Vertex Mode avails Wireless RS485 multidrop service when assigned at
this site.
•
Vertex Port
For Parani-MSP100 Vertex port no. entry.
•
Max Number of Connections
For entering the number of Hosts connectable to Parani-MSP100.
D) Repeater Mode
In Repeater Mode, Parani-MSP100 will act as a Repeater to expand the coverage of
Bluetooth. Let’s call the Parani-MSP100 that will act as Repeater, “Repeater”, and call the
Parani-MSP100 of normal operation as “Station”.
In Repeater Mode, configuration required is only the Address of the Station Parani-MSP100.
When Repeater is connecting the Station, Status LED of Repeater is blinking.
E) Serial Hub Mode
Users may transmit/receive data via Parani-MSP100 in Serial Hub mode (Serial Hub).
Parani-MSP100 in serial hub mode relay the data from a Bluetooth device to another
Bluetooth device connected to Parani-MSP100. No network host is involved.