5 s55, 6 s56, 5 sink – SENA ProBee-ZS10 User Manual
Page 66: 1 s61, 2 s62, Sink
66
ProBee-ZS10 User Guide Rev.1.5
Range
0 – 10000
7.4.5 S55
Description
Get/Set the rejoin timeout. If it is enabled, an end-device tries to rejoin the current
network when contact with the network has been lost for setting value in seconds. The
most common usage case is when an end-device can no longer communicate with its
parent and wishes to find a new one.
Execute ATS55?
ATS55=
Response
OK
OK
Default 10
Range
0 – 10000
7.4.6 S56
Description
Get/Set the end-device poll period in seconds. Adaptive polling may allow the end-
device to poll more rapidly for a short time when receiving RF data.
Execute ATS56?
ATS56=
Response
OK
OK
Default 5
Range
0 – 10000
7.5 Sink
7.5.1 S61
Description
Get/Set the sink node and the sink advertise period in seconds. When a node is
defined as a sink, it can multicast its address to the rest of the network in this period.
If set to 0, sink advertise is disabled.
Execute ATS61?
ATS61=
Response
OK
OK
Default 0
Range
0 – 10000
7.5.2 S62
Description
Get/Set the period to send Many-to-One Route Request. Many-to-One Route Request
(MTOR) creates routes from every node in the network back to this node. It is useful
when this node acts as a sink node.
Execute ATS62?
ATS62=
Response
OK