4 uart settings, 5 firmware upload, 1 local node – SENA ProBee-ZS10 User Manual
Page 58: Uart settings, Firmware upload, Local node

58
ProBee-ZS10 User Guide Rev.1.5
ATZ
Apply
the
change
OK
#
Response
AT+NWKKEY=0
# set the 128-bit network key (random key)
OK
#
Response
AT+UPDATEKEY
# update the changed network key
OK
#
Response
6.4 UART
Settings
AT+BAUDRATE=115200
# set baud rate (115,200bps)
OK
#
Response
AT+DATABIT=8
# set data bit (8bit)
OK
#
Response
AT+PARITY=0
# set parity (none)
OK
#
Response
AT+STOPBIT=1
# set stop bit (1bit)
OK
#
Response
AT+FLOWCTRL=2
# set flow control (hardware)
OK
#
Response
ATZ
Apply
the
change
OK
#
Response
6.5 Firmware
Upload
6.5.1 Local
Node
# enter the bootloader menu for uploading firmware. Note that UART of local
node should be set to 115200-8-N-1-N.
AT+BOOTLOAD
Press Enter…
EM250 Bootloader v20 b09
1. upload ebl
2. run
3. ebl info
BL >
# press “1” and upload ebl file by X-modem
begin upload
CCCCCCCCCCCCC
Serial upload complete
# press “2” or reset after upload is done