3 at+parity or at+up, 4 at+stopbit or at+us, 5 at+flowctrl or at+uf – SENA ProBee-ZS10 User Manual
Page 53: 10 firmware upload and help, 1 at+bootload or at+bl, At+parity or at+up, At+stopbit or at+us, At+flowctrl or at+uf

53
ProBee-ZS10 User Guide Rev.1.5
5.9.3 AT+PARITY
or
AT+UP
Description
Get/Set the serial parity setting on the module.
Execute AT+PARITY?
AT+PARITY=
Response
OK
OK
Default 0
Range
0 - 2
5.9.4 AT+STOPBIT
or
AT+US
Description
Get/Set the serial stop bit setting on the module.
Execute AT+STOPBIT?
AT+STOPBIT=
Response
OK
OK
Default 1
Range
1 - 2
5.9.5 AT+FLOWCTRL
or
AT+UF
Description
Get/Set flow control status. (0: none, 1: software, 2: hardware flow control)
Execute AT+FLOWCTRL?
AT+FLOWCTRL=
Response
OK
OK
Default 0
Range
0 - 2
5.10 Firmware Upload and Help
5.10.1 AT+BOOTLOAD
or
AT+BL
Description
Start bootloader to upload firmware. (blank: local, 1: passthru, 2: clone)
The device leaves the AT command line and enters the bootloader menu for uploading
new ProBee firmware. There’s no restrict to use local upload but a sleepy end-device
cannot upload to remote node over the air. The current UART should be set
115200bps, 8 data bits, no parity, 1 stop bit and none flow control.
Execute AT+BOOTLOAD
AT+BOOTLOAD=
Response
Bootloader menu
…
Serial upload complete
Please start .ebl upload image ...
Start cloning ...
Bootloader menu
…
Bootload Complete!