2 data mode, 3 security, Data mode – SENA ProBee-ZS10 User Manual
Page 57: Security

57
ProBee-ZS10 User Guide Rev.1.5
OK
#
Response
# send broadcast message(MSG04) to current network and the range is
determined by S35.
AT+BROADCAST=MSG04
OK
#
Response
6.2.2 Data
Mode
ATD
# enter the unicast mode using destination long address
OK
#
Response
MSG05+++
# send data(MSG05) and leave data mode
ATD0000
# enter the unicast mode using 16-bit short address
OK
#
Response
MSG06+++
# send data(MSG06) and leave data mode
ATD00019500002FDC40
# enter the unicast mode using 64-bit long address
OK
#
Response
MSG07+++
# send data(MSG07) and leave data mode
ATM
# enter the multicast mode using destination group ID
OK
#
Response
MSG08+++
# send data(MSG08) and leave data mode
ATM0001
# enter the multicast mode using 16-bit group ID
OK
#
Response
MSG09+++
# send data(MSG09) and leave data mode
ATB
# enter the broadcast mode
OK
#
Response
MSG10+++
# send data(MSG10) and leave data mode
AT+TRANSMITMODE=1
# set transmission mode
OK
#
Response
ATZ
Apply
the
change
OK
#
Response
MSG11+++
# send data(MSG11) and leave data mode
ATO
# return to the current data mode
6.3 Security
AT+SECURITY=1
# set security level (ON)
OK
#
Response
AT+LINKKEY=5A46…21
# set the 128-bit trust center link key (5A46…21)