beautypg.com

Typ i cal ap pli ca tions, Avail able op tions high speed pro gram ming, Two-quad rant out put: power sink – Powersolve SM800 Series User Manual

Page 5: Sequencer, High volt age isolation, Se cured volt age and cur rent set ting, Soft ware con trol and in ter faces, Dig i tal volt age and current set ting, Front power out put, 19" rack mount ing adapter

background image

SM800

May 2013

SPECIFICATIONS

Page 1 - 5

Typ i cal Ap pli ca tions

• Accurate current sources

• Automotive battery simulation

• Driving PWM-controlled DC-motors

• Electronic circuit development

• Controlled battery (dis)charging

• Medical research equipment

• Component device testing

• Lasers

• Aerospace and military equipment

• ATE in industrial production lines

In creased
Out put Power

The conservatively rated unit
allows to deliver extra output
with the same reliability.

At some derating, either the maximum output
voltage or the maximum output current can be
increased by about 10%.

Order Code - P069

Avail able Op tions

High speed
pro gram ming

A 10 to 20 times higher
programming speed (down to
0.2 ms rise time at full load)

and lower output capacitance.Excellent for
laser applications, test systems or as current
source with low parallel capacitance as used
in plasma chambers.

• Order Codes :

SM 7.5-80 P250 - SM 70-AR-24 P252
SM 18-50 P251 - SM 400-AR-4 P253

Two-Quad rant
Out put: Power sink

Two quadrant operations
maintains the output voltage
constant regardless the

output power is positive or negative. Ideal for
PWM-speed controlled DC-motors and ATE
systems.

• Order Codes :

SM 7.5-80 P245 - SM 70-AR-24 P247
SM 18-50 P246 - SM 400-AR-4 P248

Sequencer

Arbitrary Waveform generator
or standalone automation.
The se quencer is in te grated in

the Ethernet con trol ler.

Order Code - P256

High Volt age Isolation

A higher output isolation
allows series operation up to
1000V

Order Code - P089

Se cured Volt age
and Cur rent Set ting

For a maximum security,the
CV/CC settings can be
adjusted with a screwdriver

only and are protected with a plastic cap from
accidental adjusting.

Order Code - P001

Soft ware con trol
and in ter faces

Factory installed programming

interfaces:

• ISO AMP Card - isolated analog

- P249

• RS232 controller

- P254

• IEEE488 controller

- P255

• Ethernet controller (incl. sequencer)

- P256

• PROFIBUS controller

- P271

• CANBUS controller

- P272

0,4ms

Dig i tal Volt age
and current set ting

Reliable, long life digital
encoders are implemented at
the front panel.

Includes total front panel lock (also for
CV/CC-knobs) and a coarse or fine pitch
adjustment depending on the turning speed.

Order Code - P236

Front Power Out put

Blind posts at the front panel
instead of at the rear panel.

• Order Codes :

SM 7.5-80 n.a. - SM 70-AR-24 P258
SM 18-50 P257 - SM 400-AR-4 P259

19" Rack
Mount ing Adapter

The 19" mounting adapters
makes it possible to
position one or two units
side by side in a 19" rack.

• Order Code RA19 - 2SM800

Note: 1. Down load spe cial datasheet about High Speed Pro gram., Power Sink and Bat tery Charg ing from

www.powersolve.co.uk

2. There is only room for one of the in ter faces in a unit (P249, P254, P255, P256, P271 or P272).