beautypg.com

Powersolve PP500 Series User Manual

Ac-dc converter, Features

background image

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]

www.powersolve.co.uk

AC-DC Converter

Features

Universal AC Input with active PFC

Operating Temperature Range -20°C to +70°C

U-bracket low profile: 38mm

High efficiency, long life and high reliability

Remote ON/OFF Control (PP350 & PP500)

Output Short Circuit Protection

Overvoltage, Overload & Over Temperature Protections

Input Voltage

90-264VAC full range, 47-63Hz / 127-370VDC

Power Factor

>0.90 at 230VAC / >0.95 at 115VAC

AC Input Current (typ.)

2.0A at 115VAC / 1.0A at 230VAC (PP150)
2.4A at 115VAC / 1.2A at 230VAC (PP200)
4A at 115VAC / 2A at 230VAC (PP350)
6A at 115VAC / 3A at 230VAC (PP500)

Inrush Current

30A at 115VAC / 60A at 230VAC (PP150)
25A at 115VAC / 50A at 230VAC (PP200)
22A at 115VAC / 44A at 230VAC (PP350)
30A at 115VAC / 50A at 230VAC (PP500)

Leakage Current

<1mA at 230VAC (PP150) / <2mA at 230VAC (PP200,PP350,PP500)

Output Voltage

See Table

Output Current

See Table

Voltage Tolerance

±1% (PP150) / ±2% (PP200,PP350,PP500)

Overload Protection

>110-135% (PP150) / >105% (PP200,PP350,PP500) of rated output power.

Overvoltage Protection

115-150% of rated output voltage.

Over Temperature Protection

90°C ±5°C (PP150 & PP200)
100°C ±5°C (PP350)
95°C ±5°C (PP500)

Operating Temperature Range

-20°C to +70°C. Above 50°C, derate linearly to 50% load at 70°C (PP150,PP200)
-20°C to +65°C. Above 50°C, derate linearly to 50% load at 65°C (PP350)
-20°C to +60°C. Above 50°C, derate linearly to 65% load at 60°C (PP500)

Operating Humidity

20-90% RH non-condensing

Storage Temperature Range

-20°C to +85°C (PP150) / -40°C to +85°C (PP200,PP350,PP500)

Storage Humidity

10-95% RH non-condensing

Temperature Coefficient

±0.05%/°C (0-50°C) (PP150) / ±0.03%/°C (0-50°C) (PP200,PP350,PP500)

Vibration

10-500Hz, 2G 10min/1 cycle, period 60 mins. Each along X, Y & Z axis

Safety Standards

UL60950-1 2nd Edition, TUV EN60950-1: 2006+A11 Approved

Withstand Voltage

I/P-O/P: 4242VDC, I/P-FG: 2121VDC for 1 minute

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100MΩ / 500VDC

EMI Conduction & Radiation

EN55022: 2006 Class B, EN61204-3: 2000, EN61000-6-3: 2007

Harmonic Current

EN61000-3-2: 2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005: 2008

EMS Immunity

EN55024: 1998+A1: 2001+A2: 2003 light industry level, criteria A, EN61204-3: 2000,

Cooling

Convection cooling (PP150, PP200)
Convection cooling up to 300W, 10.5CFM fan for 350W (PP350)
Convection cooling up to 400W, 23.5CFM fan for 500W (PP500)

Dimensions

198(L) x 68(W) x 33(H) mm (PP150)
202(L) x 101.5(W) x 38(H) mm (PP200)
231(L) x 101.5(W) x 38(H) mm (PP350)
254(L) x 127(W) x 38(H) mm (PP500)

Weight

0.42Kg (PP150)
0.70Kg (PP200)
1.06Kg (PP350)
1.70Kg (PP500)

Electrical Specification

PP150: 198(L) x 68(W) x 33(H)mm
PP200: 202(L) x 101.5(W) x 38(H) mm
PP350: 231(L) x 101.5(W) x 38(H) mm
PP500: 254(L) x 127(W) x 38(H) mm

PP150/PP200/PP350/PP500 Series
150W - 500W Active PFC