3 ramp stretching – R&M Materials Handling VARIABLE SPEED CONTROLS ControlMaster Select Service Manual User Manual
Page 28

R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319
28/46
R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.
6.2.3 Ramp stretching
The inverter allows stretching the ramp on the generating side. The ramp stretching is adjustable as
percentage of nominal deceleration distance. The default stretch of the normal ramp is 40% of the
nominal deceleration distance.
If the inverter cannot stop with the set ramp stretching, it will stop by brake and show fault code. F56
Generator side current limit.
S1
3
1
2
f
0
4
= A
= B
1 Normal
ramp
2 0.5s
ramp
3 Current
limit
4
Motor current at current limit level