Duro-Last XPS Fan Fold - A (Hybrid Crush_Cut Fold) User Manual
Page 2
Duro-Last, “World’s Best Roof” and Duro-Guard are registered marks owned by Duro-Last, Inc.
Updated: 12/4/2013
2 of 2
www.duro-last.com
800-248-0280
DURO-GUARD
®
XPS FAN FOLD – A
Installation:
Duro-Guard XPS Fan Fold – A may be used
directly under the Duro-Last membrane.
Ensure that “bare” XPS is never in direct
contact with the Duro-Last membrane.
Refer
to the appropriate Duro-Last specification
for slip sheet and cover board
requirements.
Panels must be kept dry before, during and
after installation. Install only as much fan fold
board as can be covered the same day with
completed roofing.
Abut panel edges together and stagger joints of
adjacent panels.
Boards must be neatly fitted to roof deck and
around penetrations with no gaps greater than
¼ inch.
Refer to the appropriate Duro-Last roof system
specification and detail drawings for deck
preparation and other requirements.
Precautions must be taken to ensure that new
concrete decks have fully cured and do not
continue to release moisture.
Fan Fold Attachment:
Mechanical Attachment
Refer to Duro-Last Mechanically Attached
System Specifications and Detail Drawing
#1030 for approved fasteners and fastening
patterns.
Use fasteners and plates supplied by, or
approved by, Duro-Last, Inc.
Storage:
Fan fold board must be protected from open
flame and kept dry at all times.
Factory applied packaging is intended only for
protection during transit. Slit or remove the
packaging to prevent accumulation of
condensation.
Store elevated (at least 3”) and completely
covered with a weatherproof covering such as
a tarpaulin.
Do not use panels which are wet or damaged.
Limitations:
Duro-Last, Inc. will not be responsible or liable
for any defects or problems related to building
or roof design by others, to deficiencies in
construction, to dangerous conditions on the
job site, or to improper storage, handling or
installation by others.
Figure 3. Duro-Guard XPS Fan Fold – A as a recover
board
Figure 4. Partial view of facer on top surface