beautypg.com

Duro-Last ISO III CG User Manual

Duro-guard, Iso iii cg, Flat and tapered panels

background image

Duro-Last, “World’s Best Roof” and Duro-Guard are registered marks owned by Duro-Last, Inc.

Updated: 10/30/2013

DURO-GUARD

®

ISO III CG

FLAT AND TAPERED PANELS

1 of 2

www.duro-last.com 800-248-0280

Figure 1. Duro-Guard ISO III CG Flat On Steel Deck

TABLE 1. TYPICAL TAPER PANEL DIMENSIONS

ID SLOPE* SIZE

MIN

MAX

Q

½” per ft.

4%

4 ft. x 4 ft.

½”

2-½”

QQ

½” per ft.

4%

4 ft. x 4 ft.

2-½”

4-½”

X

¼” per ft.

2%

4 ft. x 4 ft.

½”

1-½”

Y

¼” per ft.

2%

4 ft. x 4 ft.

1-½”

2-½”

G

¼” per ft.

2%

4 ft. x 4 ft.

1”

2”

H

¼” per ft.

2%

4 ft. x 4 ft.

2”

3”

AA

⅛” per ft.

1%

4 ft. x 4 ft.

½”

1”

A

⅛” per ft.

1%

4 ft. x 4 ft.

1”

1-½”

B

⅛” per ft.

1%

4 ft. x 4 ft.

1-½”

2”

C

⅛” per ft.

1%

4 ft. x 4 ft.

2”

2-½”

* Contact Duro-Last for additional slope options.

Figure 2. Duro-Guard ISO III CG Taper

Description:

Duro-Guard

®

ISO III CG is a closed-cell

polyisocyanurate foam core insulation board with an
integrally laminated, heavy, durable and
dimensionally stable coated-glass facer which is
compatible with Duro-Last

®

roof membranes.

 Available in both flat and tapered panels in

order to meet thermal insulation needs as well
as provide slope for proper roof drainage.

 Manufactured with a blowing agent that has

zero ozone depletion potential (ODP) and
virtually no global warming potential (GWP).

 Approved for direct application to steel and

other deck types.

 Available in two grades of compressive

strength per ASTM C 1289.
o Type II, Class 1, Grade 2 (20 psi).
o Type II, Class 1, Grade 3 (25 psi).

 Refer to Table 3 for physical properties.

Recommended Uses:

 Mechanically attached Duro-Last roof systems.
 Adhered/Fully Bonded Duro-Last roof systems.
 Duro-Bond

®

roof systems.

 Metal retrofit roof systems.

Underwriters Laboratories, Inc. Classifications:

 In some cases, use of this product may result

in a Class A or B fire rating over a combustible
deck without the use of a fire rated slip sheet or
board. Refer to Duro-Last’s UL Listings
(TGFU.R10128) for assembly details.

 UL 1256, UL 790.
 Insulated Metal Deck Constructions:

o No. 120, 123, 292.

 UL 263 Hourly Rated P Series Roof

Assemblies.

 UL Classified for use in Canada.

Factory Mutual Approvals:

 FM 4450, FM 4470.
 Approved for Class 1 insulated steel, wood,

concrete and gypsum roof deck construction.

 Refer to FM Approval’s RoofNav for details on

FM Approved systems (www.roofnav.com).

Flat Panels:

 Available

sizes:

o 4 ft. x 4 ft.
o 4 ft. x 8 ft.
o Thicknesses: 1 to 4 inches.

 Refer to Table 2 for R-value and flute

spanability.

Tapered Panels:

 Available

sizes:

o 4 ft. x 4 ft.
o Thicknesses: ½ to 4-½ inches.

 Precut miters and crickets are also available.
 Taper designs and shop drawings available.