ISO NB

1 of 2

www.duro-last.com 800-248-0280

TABLE 1. THERMAL VALUES

THICKNESS*

LTTR

R-VALUE

FLUTE SPANABILITY

(inches) (mm)

(inches) (mm)

1.50 38

6.20

4.625

111

2.00 51

9.10

4.375

111

2.50 64

12.00

4.375

111

3.00 76

15.00

4.375

111

3.50 89

18.00

4.375

111

4.00 102

21.10

4.375

111

4.50 114

24.20

4.375

111

* Contact Duro-Last for additional thickness options.

Figure 1. Duro-Guard ISO NB (Top Layer)

Description:

Duro-Guard

®

ISO NB is a rigid roof insulation

composite panel composed of a closed cell
polyisocyanurate foam core bonded during the
manufacturing process to fiber reinforced facers on
one side and either 7/16 or 5/8 inch oriented strand
board (OSB) on the other.

 A superior combination of high insulating

properties and a nailable surface.

 Foam core manufactured with a blowing agent

that has zero ozone depletion potential (ODP)
and virtually no global warming potential
(GWP).

 Approved for direct application to steel and

other deck types.

Duro-Guard ISO NB is not a structural

panel, and is suitable only for installation
over fully supported structural decks.

 Incorporates

APA-TECO Rated Exposure 1

OSB.

 Also available with plywood.
 Foam core available in two grades of

compressive strength per ASTM C 1289.
o Type II, Class 1, Grade 2 (20 psi).
o Type II, Class 1, Grade 3 (25 psi).

 Refer to Table 2 for physical properties.

Recommended Uses:

 Underlayment for Exceptional

®

Metals standing

seam metal roofs.

 Mechanically attached Duro-Last

®

roof

systems.

 Adhered/Fully Bonded Duro-Last roof systems.
 Duro-Bond

®

roof systems.

 Metal retrofit roof systems.

Underwriters Laboratories, Inc. Classifications:

 UL

1256.

 Insulated Metal Deck Constructions:

o No. 120, 123, 292.

 UL

790.

 UL 263 Hourly Rated P Series Roof

Assemblies.

 UL Classified for use in Canada.

Factory Mutual Approvals:

 FM 4450, FM 4470.
 Approved for Class 1 insulated steel deck

construction.

 Refer to FM Approval’s RoofNav for details on

FM Approved systems (www.roofnav.com).

Flat Panels:

 Available

sizes:

o 4 ft. x 4 ft.
o 4 ft. x 8 ft.
o Thicknesses: 1.5 to 4.5 inches.

 Refer to Table 1 for R-value and flute

spanability.