DATA SHEET
Vented Ridge Cap
“Duro-Last” and “EXCEPTIONAL” are registered marks owned by Duro-Last Roofing, Inc.
Revised 8/30/2012
Description:
The Vented Ridge Cap can provide proper ventilation to
an attic.
Fabricated from 24-gauge vinyl-coated metal
with or without a
6” Duro-Last
®
membrane skirt.
Available in 10’ lengths extending 8” out each
side from the peak.
Splice plates are used to join sections, if
necessary.
Available in white, tan, gray and dark gray.
Contact Duro-Last or EXCEPTIONAL
®
Metals to
request a color chart, samples and information
regarding custom metals and finishes.
Energy Efficiency:
LEED
®
and ENERGY STAR
®
compliant; Recyclable.
Installation:
1.
Install in accordance with Duro-Last detail
drawing #4200 and #4200 installation.
2.
Any deviation from the requirements set forth in
the detail drawings must be pre-approved, in
writing, by the EXCEPTIONAL Metals Technical
Department.
Warranty:
Duro-Last offers a wide range of warranty coverage for
EXCEPTIONAL Metals products when used with the
Duro-Last roofing system, including paint and finish.
Technical Services:
Product samples, detail sheets, color chips, and color
chart are available for your submittal package. For
assistance with questions or submittals, contact your
local representative or call EXCEPTIONAL Metals.
Notes:
Required Ventilation area for attic area without vapor
retarder is 1sf (ventilation) /150sf of attic area.
Required Ventilation for new construction that provides
a vapor retarder is 1sf (ventilation) / 300sf attic area.
Required Ridge Vent area can be reduced to 50% of
total required ventilation area, if the remaining area is
located in the eaves for a balanced system.
To determine required ventilation area, take attic area
and divide by either 150sf or 300sf (depending on if a
vapor retarder is present) and this will give the
required net free ventilation area (ft²).Duro-Last Ridge
vent provides 16 in² of net free area per lineal foot.
Contractor is responsible for compliance with all state
and local building codes.
Attic Area
Length of
Ridge
Length of
Ridge
ft²
ft²
in²
ft
ft²
in²
ft
1000
6.7
965
60
3.4
482
30
1200
8.0
1158
72
4.0
579
36
1400
9.4
1351
84
4.7
675
42
1600
10.7
1544
96
5.4
772
48
1800
12.1
1737
109
6.0
868
54
2000
13.4
1930
121
6.7
965
60
2200
14.7
2123
133
7.4
1,061
66
2400
16.1
2316
145
8.0
1,158
72
2600
17.4
2508
157
8.7
1,254
78
2800
18.8
2701
169
9.4
1,351
84
3000
20.1
2894
181
10.1
1,447
90
3200
21.4
3087
193
10.7
1,544
96
3400
22.8
3280
205
11.4
1,640
103
Ridge Vent Area
w/o Eave Vents
Ridge Vent Area
with Eave Vents
Attic Area
Length of
Ridge
Length of
Ridge
ft²
ft²
in²
ft
ft²
in²
ft
1000
3.3
475
30
1.7
238
15
1200
4.0
570
36
2.0
285
18
1400
4.6
665
42
2.3
333
21
1600
5.3
760
48
2.6
380
24
1800
5.9
855
53
3.0
428
27
2000
6.6
950
59
3.3
475
30
2200
7.3
1045
65
3.6
523
33
2400
7.9
1140
71
4.0
570
36
2600
8.6
1236
77
4.3
618
39
2800
9.2
1331
83
4.6
665
42
3000
9.9
1426
89
5.0
713
45
3200
10.6
1521
95
5.3
760
48
3400
11.2
1616
101
5.6
808
50
Ridge Vent Area
w/o Eave Vents
Ridge Vent Area
with Eave Vents
Ventilation Requirements with Vapor Retarder