beautypg.com

Duro-Last ISO HD Composite User Manual

Duro-guard, Iso hd composite

background image

Duro-Last, “World’s Best Roof” and Duro-Guard are registered marks owned by Duro-Last, Inc.

Updated: 10/31/2013

DURO-GUARD

®

ISO HD Composite

1 of 2

www.duro-last.com 800-248-0280

Figure 1. Duro-Guard ISO HD Composite (Top Layer)

Description:

Duro-Guard

®

ISO HD Composite is comprised of

½ inch high density polyisocyanurate (ISO) cover
board laminated during the manufacturing process to
Duro-Guard ISO III rigid roof insulation. R-value is
optimized with a thinner profile.

 Eliminates the need for a cover board while

saving on inter-ply adhesive and labor.

 Manufactured with a blowing agent that has

zero ozone depletion potential (ODP) and
virtually no global warming potential (GWP).

 Recycled content of cover board > 8%.
 Approved for direct application to steel and

other deck types.

 Top layer of ½ inch high density ISO provides

100 psi compressive strength.

 The bottom layer of Duro-Guard ISO III is

available in two grades of compressive strength
per ASTM C 1289:
o Type II, Class 1, Grade 2 (20 psi).
o Type II, Class 1, Grade 3 (25 psi).

 Passes ASTM Resistance to Mold Test.
 Refer to Tables 2 and 3 for physical properties.

Recommended Uses:

 Mechanically attached Duro-Last

®

roof

systems.

 Adhered/Fully Bonded Duro-Last roof systems.
 Duro-Bond

®

roof systems.

 Metal retrofit roof systems.

Underwriters Laboratories, Inc. Classifications:

 In some cases, use of this product may result

in a Class A or B fire rating over a combustible
deck without the use of a fire rated slip sheet or
board. Refer to Duro-Last’s UL Listings
(TGFU.R10128) for assembly details.

 UL

1256.

 Insulated Metal Deck Constructions.

o No. 120, 123, 292.

 UL

790.

 UL 263 Hourly Rated P Series Roof

Assemblies.

 UL Classified for use in Canada.

Factory Mutual Approvals:

 FM 4450, FM 4470.
 Approved for Class 1 insulated steel, wood,

concrete and gypsum roof deck construction.

 Refer to FM Approval’s RoofNav for details on

FM Approved systems (www.roofnav.com).

Flat Panels:

 Available

sizes:

o 4 ft. x 4 ft.
o 4 ft. x 8 ft.
o Thicknesses: 2 to 4.5 inches.

 Refer to Table 1 for R-value and flute

spanability.

TABLE 1. THERMAL VALUES

THICKNESS

LTTR

R-VALUE*

FLUTE SPANABILITY

inches mm

inches

mm

2.00 51

11.00

4.375

111

2.25 57

12.10

4.375

111

2.50 64

13.90

4.375

111

3.00 76

16.90

4.375

111

3.25 83

18.10

4.375

111

3.50 89

19.90

4.375

111

4.00 102

23.00

4.375

111

4.25 108

24.20

4.375

111

4.50 114

26.10

4.375

111

* R-Value is calculated by adding the R-value of the cover board

and the R-value of Duro-Guard ISO III together.