TECHNICAL DATA

APPLICABLE STANDARDS

Underwriters Laboratories, Inc. (UL) -
UL 1897 Standard for Safety for Uplift

Tests for Roof Covering Systems.

Note: INSTA-STIK Professional Roof
Insulation Adhesive meets the
requirements of UL 1897 wind uplift
resistance tests for steel deck

applications. If INSTA-STIK is used in a

UL Class A rated roofing system, the
roofing system will maintain its UL Class

A rating.

APPROVALS

FM GLOBAL (FM)
INSTA-STIK Professional Roof
Insulation Adhesive meets the
requirements of the following FM fire

and wind uplift resistance tests for FM
approved roof deck application:

FLAT (Specific Roof Assembly)
· Class 1-60

· Class 1-90

· Class 1-135

· Class 1-150

· Class 1-165

· Class 1-180

· Class 1-195

· Class 1-210

· Class 1-225

· Class 1-240

· Class 1-270

TAPERED (Specific Roof Assembly)

· Class 1-135

· Class 1-150

· Class 1-165

· Class 1-180

· Class 1-195

· Class 1-240

· Class 1-315

Dade County (Florida)

INSTA-STIK Professional Roof
Insulation Adhesive meets the

requirements of Metropolitan Dade
County, Florida, windstorm and fire
classifications for roof deck applications.
Miami Dade Notice of Acceptance
Number - 02-0726.01, expires

10/10/2007

INSTALLATION

The ideal product temperature at the
time of application should be 75°F

(24°C). The minimum ambient and
surface temperatures must be 33°F
(0.6°C) and rising. INSTA-STIK is
packaged in a single container that
should be stored between 50°F (10°C)
and 75°F (24°C). At these

temperatures, the shelf life is 15 months
from the date of manufacture.

SAFETY

When dispensing INSTA-STIK, the
applicator must wear protective clothing,
work gloves, and protective eyewear.

SURFACE PREPARATION

All surfaces must be free of any ice,
snow, frost, debris, dirt, dust, grease,
oil, diesel fuel and standing water before

INSTA-STIK is applied.

Re-Cover Over Bituminous Asphalt
(BUR)

A licensed INSTA-STIK instructor,
authorized to perform adhesion tests,

must be on site prior to the
commencement of the project to

determine compatibility. Please contact

Duro-Last ES department at least

fourteen (14) days in advance for
further instructions.

STEEL DECK

The upper flange of the steel deck must

be free of any debris, dirt, dust, grease,

oil, diesel fuel, standing water, ice, snow
or frost. On new steel, the residual
shop-oil coatingmust be removed using

Red Devil TSP90 or equivalent,

acetone, naphtha, or comparable
cleaner.

INSULATION

Review the roofing insulation plan. The

roof insulation boards to be attached
must be no larger than 4' × 4' (1.2 m ×

1.2 m). In multiple layers of insulation,

the staggered joint method must be

used to eliminate thermal breaks.

PRODUCT & EQUIPMENT
INSTALLATION

lNSTA-STIK Professional Roof
Insulation Adhesive should be mixed
prior to use by firmly holding the
container on its side and agitating the
contents using a side-to-side motion for
at least 15 seconds. Attach the

dispensing hose swivel end to the
cylinder valve. Tighten the connection

using an open-end wrench being careful
not to over tighten. Verify that the on/off

valve on the dispensing hose is closed.
The handle should be perpendicular to
the valve. Attach the dispensing wand

kit to the brass valve by screwing it in
until it is hand tight. The dispensing

wand kit is recommended for roof decks
with many penetrations or confined

areas.

IMPORTANT: When applying
INSTA-STIK, the insulation boards must
be placed onto the INSTA-STIK beads

within 5 minutes. Walk on the boards to
spread the beads for maximum contact.

Continue to walk on the insulation
boards every 5-7 minutes until the
insulation is firmly attached, usually

15-45 minutes.

Figure 4: Installation using INSTA-STIK™ Complete

HANDLING CHARACTERISTICS

Temperature, Humidity

Tack Free Time

40 °F (4 °C),

50% relative humidity

45 min.

75 °F (24 °C),

50% relative humidity

15 min.

120 °F (49 °C),

25% relative humidity

13 min.

INSTA-STIK PROFESSIONAL INSULATION ADHESIVE