APPENDIX A: DEFAULT SERVER SETTINGS

Setting Default Value

Server Name MODEL NUMBER

Serial Number printed on side of unit

Password password field is blank from factory

DHCP Enable

IP Address BASED ON DHCP SERVER

If a DHCP assignment is not available, the

device will default to 169.254.102.39

Net Mask 255.255.255.0

Gateway 169.254.102.100

MAC Address Fixed - see bottom label

Firmware Version X.X.X (Current Version)

Hardware Version X.X (Current Version)

Port 1, 2

Serial port mode RS-232

Baud Rate 9600

Data bits 8

Parity None

Stop bits 1

Flow Control None

Protocol TCP

Serial timeout 0 seconds

TCP alive timeout 0 minutes
Connection Mode Server

Delimiter HEX 1 00
Delimiter HEX 2 00

Remove delimiters Disable

Force transmit 0 ms

Inter-character timer 0 ms

Character count 0

TCP/UDP port Port 1 = 4000, Port 2 = 4001