3 writing a new sms to storage, At+cmgw=""

Page 68

background image





GM862-QUAD / PY Software User Guide

1vv0300747 Rev. 3 - 10/07/07

Reproduction forbidden w ithout Telit Communications S.p.A. w ritten authorization - All Rights Reserved

page 68 of 96

2- Let's assume you have the IRA code 0x6B and you want to find the corresponding character:
From the table you find at the position
- most significant Nibble: 6
- least significant Nibble: B
Hence, the character corresponding to the 0x6B IRA code is 'k'.


TIP: With the command AT+CSCS is possible to select the character set; the available types
are:
“IRA” - ITU-T.50
”8859-1” - ISO 8859 Latin 1
”PCCP437” - PC character set Code Page 437.
”UCS2” - 16-bit universal multiple-octet coded character set (ISO/IEC10646)

Please refer to the AT Commands Reference Guide for the full command description

3.5.3 Writing a New SMS to storage

A new SMS can be written in the selected storage (in the current SW version only "SM" is
supported) and then can be sent to the desired destination.
To write the new SMS:

send command

AT+CMGW=""

where:

: destination address

wait for prompt "

>

"

send SMS text (MAX 160 characters)

end command with CTRL-Z character (0x1A hexadecimal) or abort command with ESC character

(0x1B hexadecimal)

wait for response:

Response

Reason

Action

+CMGW:

OK

Message has been successfully
written in position number

proceed ahead

ERROR

some error occurred

Enable the extended error
codes report (see par.2.5.2.1)
and retry.

+CMS ERROR: 330

SMSC address unknown

Insert SMSC address (see par.
3.5.1.3)

+CMS ERROR: 322

Memory Full

memory is full, hence delete
some records and retry.