3 closing the data call, 1 exit the data mode and enter the command mode, 2 hang up the data call – Rainbow Electronics GM862-QUAD-PY User Manual
Page 29: Ath

GM862-QUAD / PY Software User Guide
1vv0300747 Rev. 3 - 10/07/07
Reproduction forbidden w ithout Telit Communications S.p.A. w ritten authorization - All Rights Reserved
page 29 of 96
command:
ATD 0404192111
response
CONNECT 9600
2- Let's assume you have to call the national number but in international format +39-40-4192111,
command:
ATD +39404192111
response
CONNECT 9600
3- Let's assume you have to call the international number +386-40-4192111,
command:
ATD +386404192111
response
CONNECT 9600
2.7.3 Closing the Data call
2.7.3.1 Exit the data mode and enter the command mode
•
Send escape sequence
+++
•
wait the escape sequence pause time ( see S12 parameter)
•
wait for response
OK
NOTE: After the Escape sequence and during the call the only command that is accepted by
the GM862-QUAD / PY is the ATH. All the other commands are not supported during a call.
TIP: during the escape sequence pause time S12 no further characters should be sent to the
device in order to enter the command mode.
2.7.3.2 Hang up the data call
•
Send command
ATH
•
wait for response
NO CARRIER
TIP: during the data call the device remains in data (on line) mode, so the escape sequence
(+++) must be issued before sending AT commands to the device.