3.4.1 Enabling/Disabling the power saving function
Send command
AT+CFUN=[
where:
Parameters:
0 - minimum functionality, NON-CYCLIC SLEEP mode: in this mode, the AT interface is not
accessible. Consequently, once you have set
Otherwise these characters remain in the input buffer and may delay the output of an unsolicited
result code. The first wake-up event stops power saving and takes the ME back to full functionality
level
1 - mobile full functionality with power saving disabled (factory default)
2 - disable TX
4 - disable either TX and RX
5 - mobile full functionality with power saving enabled
0 - do not reset the ME before setting it to
•
wait for response:
Response
Reason
Action
OK
The power save is now active
ERROR
some error occurred
Enable extended result codes
(see par. 2.5.2.1), and retry.
+CME ERROR: 4
operation not supported
Check command syntax and
TIP: The power saving function is disabled by default when the device starts up, in order to
guarantee that even without the DTR line support it is possible to exchange commands with
the module; for this reason the power saving setting command shall be issued after every
power up.