beautypg.com

Ata6823 [preliminary, Schaffner and electromagnetic compatibility, 1 transients on power-supply rail (battery) – Rainbow Electronics ATA6823 User Manual

Page 24

background image

24

4856E–AUTO–07/07

ATA6823 [Preliminary]

10. Schaffner and Electromagnetic Compatibility

10.1

Transients on Power-supply Rail (Battery)

The application (including IC and external protection circuitry, see

Figure 1-1 on page 2

) has to

withstand the test pulses in

Table 10-1

.

Figure 10-1. Pulse 1 (R

i

= 10

)

Figure 10-2. Pulse 2 (R

i

= 10

)

Table 10-1.

Test Pulses

Test

Pulse No.

Test

Level

Duration or Number

of Pulses

Specs

Acceptance

level

1

–100V

10 min

R

i

= 10

A

2

150V

10 min

R

i

= 10

A

3a

–200V

10 min

R

i

= 50

A

3b

200V

10 min

R

i

= 50

A

4

4V/5.5V

15 ms/2s

R

i

= 0.01

A

5

40V

5 pulses, 1 minute

recurrence period

R

i

= 0.5

, t

d

= 400 ms, t

r

= 5 ms

B

t

10%

< 100

µ

s

1 ms

5s

1

µ

s

200 ms

-100V

12V

V

90%

t

2

µ

s

50

µ

s

50

µ

s

200 ms

V

150V

12V

90%

10%