Rc2100 – Rainbow Electronics RC2100 User Manual
Page 6

RC2100
2005 Radiocrafts AS
RC2100 Data Sheet (rev. 1.0)
Page 6 of 22
The RF protocol and the configuration commands are described in general in the RC232™
User Manual. The complete list of configurable parameters stored in non-volatile memory that
apply for RC2100 is given in the table “Configuration Memory” page 9. For configurable
parameters not stored in non-volatile memory and other configuration commands, please
refer to the RC232 User Manual.
The supply voltage is connected to the VCC pin. The module contains an internal voltage
regulator and can therefore operate over a wide supply voltage range. The regulated voltage
is available at the VDD pin, but should not be used to supply external circuits.
The ON/OFF pin can be used to turn the module completely off, and hence reduce the power
consumption to a minimum. For normal operation the ON/OFF pin must be connected to
VCC. To turn the module completely off, connect the ON/OFF pin to ground (logic low level).
See also Power Management page 12.