beautypg.com

Timer 3 capture register, Timer 3 capture register (t3cp) byte read, Synchronous serial interface (ssi) – Rainbow Electronics T48C862-R4 User Manual

Page 66: Ssi features

background image

66

T48C862-R4

4551B–4BMCU–02/03

Timer 3 Capture Register

The counter content can be read via the capture register. There are two ways to use the
capture register. In modes 1 and 4, it is possible to read the current counter value
directly out of the capture register. In the capture modes 2, 3, 5 and 12, a capture event
like an edge at the Timer 3 input or a signal from Timer 2 stores the current counter
value into the capture register. This counter value can be read from the capture register.

Timer 3 CaPture Register
(T3CP) Byte Read

Address: "B"hex - Subaddress: "4"hex

Synchronous Serial
Interface (SSI)

SSI Features:

With Timer 1:

2- and 3-wire NRZ

2-wire mode multi-chip link mode (MCL), additional internal 2-wire link for
multi-chip packaging solutions

With Timer 2:

Biphase modulation

Manchester modulation

Pulse-width demodulation

Burst modulation

With Timer 3:

Pulse-width modulation (PWM)

FSK modulation

Biphase demodulation

Manchester demodulation

Pulse-width demodulation

Pulse position Demodulation

High Nibble

First read cycle

Bit 7

Bit 6

Bit 5

Bit 4

Reset value: xxxxb

Low Nibble

Second read cycle

Bit 3

Bit 2

Bit 15

Bit 0

Reset value: xxxxb