4551B–4BMCU–02/03
Timer 3 Capture Register
The counter content can be read via the capture register. There are two ways to use the
capture register. In modes 1 and 4, it is possible to read the current counter value
directly out of the capture register. In the capture modes 2, 3, 5 and 12, a capture event
like an edge at the Timer 3 input or a signal from Timer 2 stores the current counter
value into the capture register. This counter value can be read from the capture register.
Timer 3 CaPture Register
(T3CP) Byte Read
Address: "B"hex - Subaddress: "4"hex
Synchronous Serial
Interface (SSI)
SSI Features:
•
With Timer 1:
–
2- and 3-wire NRZ
–
2-wire mode multi-chip link mode (MCL), additional internal 2-wire link for
multi-chip packaging solutions
•
With Timer 2:
–
Biphase modulation
–
Manchester modulation
–
Pulse-width demodulation
–
Burst modulation
•
With Timer 3:
–
Pulse-width modulation (PWM)
–
FSK modulation
–
Biphase demodulation
–
Manchester demodulation
–
Pulse-width demodulation
–
Pulse position Demodulation
High Nibble
First read cycle
Bit 7
Bit 6
Bit 5
Bit 4
Reset value: xxxxb
Low Nibble
Second read cycle
Bit 3
Bit 2
Bit 15
Bit 0
Reset value: xxxxb