5. To lock LM2’s front panel from log reset and

adjustments, press and hold the Utility key. Note: Extra

info about loudness and true-peak level may still be

accessed on Stats page by pushing the Home key.

Loudness Glossary
The many new standards, loudness and true-peak level

terms may be difficult to keep track of. Find an updated

glossary at the TC Electronic website at

www.tcelectronic.com/loudness

QUICk gUIdE

Master Control Logging
LM2 monitors loudness continuously 24/7. Dump log

files to a PC or a Mac or bring up the Radar view using

the Icon application. Note that a computer may monitor

multiple LM2 units, and that it is not necessary to

connect one, except for dumping log files every now and

then.

1. Press the Recall key and use the dial to find a “Meter”

preset, i.e. “EBU Mode R128” or “ATSC Mode A/85”

2. Press the Enter key to confirm recall of preset. Note: A

preset recall resets the meter history and the log.

3. LM2’s default input is AES/EBU. Change input if

needed using the I/O key, arrow keys and the dial.

4. To lock LM2’s front panel from log reset and

adjustments, press and hold the Utility key. Note: Extra

info about loudness and true-peak level may still be

accessed on Stats page by pushing the Home key.

Master Control Limiting
On top of 24/7 logging, LM2 can be used as a precision

true-peak limiter. Dump log files to a PC or a Mac or

bring up the Radar view using the Icon application. Note

that a computer may monitor multiple LM2 units, and that

it is not necessary to connect one, except for dumping

log files every now and then.

1. Press the Recall key and use the dial to find a “Limit”

preset, i.e. “EBU R128 Limit” or “ATSC A/85 Limit”

2. Press the Enter key to confirm recall of preset. Note: A

preset recall resets the meter history and the log.

3. LM2’s default input is AES/EBU. Change input if

needed using the I/O key, arrow keys and the dial.

4. To adjust the limit threshold of LM2, press the Edit key

and find the “Lim Thres TP” parameter.