LM2 & TC ICON

or changing the Time Reference, resets the meter and

descriptor history.

Low Level Below
Determines where the shift between green and blue

happens in the outer ring. It indicates to the engineer that

level is now at risk of being below the noise floor.

Alert Indicator
Range: Off/Stereo Integrity

The Alert indicator is located on the Radar page and

indicates suspected lack of stereo integrity based on

measuring the difference of left/right outputs. If an

average difference of 3 dB or more between left and right

channels is meassured over a prolonged time, the LED

is lit.

More alert functions may become available with new

versions of LM2 software

Peak Indicator
This parameter sets at which level the peak indicator will

be invoked.

The remaining parameters are described earlier in this

manual.