Chapter 7 – Printronix N7000 H-Series Cartridge Ribbon Printer User Manual
Page 198

198
Chapter
7
Diagnosing Problems
HMR BANK FAN FLT
Yes
Sensors cannot detect
current in fan circuit.
Check that fan cable is connected.
Check for obstruction of vents and
fan airway; remove any
obstructions. Check for items
beneath the printer blocking cabinet
vents. Power back on the printer. If
this message recurs, contact your
authorized service representative.
1
ILL EXT BUS ACC*
No
Illegal External Bus
Access. Firmware error
on the controller board.
Contact your authorized service
representative.
1
ILL INST ACCSS*
No
Illegal Instruction
Accessed. Firmware
error on the controller
board.
Contact your authorized service
representative.
1
ILLGL OPR ACCSS*
No
Illegal Operand
Accessed. Firmware
error on controller board.
Contact your authorized service
representative.
1
INCOMPAT E-NET
Remove NIC
Yes
Incompatible network
interface card (NIC) is
installed.
Install a compatible NIC to the
printer then reboot. If this message
still appears, contact your
authorized service representative.
1
INTAKE FAN FAULT
Yes
Sensors cannot detect
current in fan circuit.
Cycle power. If the message
appears, press CLEAR. If the
message does not clear, contact
your authorized service
representative.
1
INTERRUPT UNUSED
VECTOR 00
No
The controller board
receives an interrupt it
does not understand. The
problem can be created
by electrical noise, by a
software problem, or by a
hardware problem.
Cycle power. If this message
occurred once and never again, you
can ignore it. If the message
reappears or appears consistently,
contact your authorized service
representative.
1
LO DRV. SHORT*
No
Lower Driver Short.
Circuit(s) on the hammer
bank or in the hammer
bank power cable
shorted to ground.
Contact your authorized service
representative.
1
LOAD PAPER
Yes
Printer is out of paper.
Load paper and press CLEAR.
Table 12. N7000 STD ASCII LCD Fault Messages Troubleshooting
Displayed Message
Can User
Correct?
Explanation
Solution