3 pstn port (a/b line), Pstn port (a/b line) -7 – VEGA Phoenix PSI Data Fax Modem User Manual
Page 17
![background image](/manuals/265241/17/background.png)
PSI-DATA/FAX-MODEM/RS232 Industrial Modem
692302
1-7
1.4.3
PSTN Port (a/b Line)
Connection
Shield
Operating modes
Dial-up method
Transmission rate
- DCE/DCE
- Fax
Compatibility
Fax compatibility
Instruction set compatibility
Error correction
Data compression
RJ-12, 6-pos. or plug-in COMBICON screw terminal
block
DC coupled on DIN rail
Dial-up modem, 2-wire half/full duplex
Fax modem, 2-wire half duplex
Permanent line, 2-wire full duplex
Multi-frequency/pulse dial configurable via software
Automatic adjustment according to V.8
300 baud to 33.6 kbaud
2400 baud to 14.4 kbaud
ITU V.42bis, V.42, V.34 extended, ITU V.32bis, V.32,
V.21, V.22bis, V.22, V.23, Bell 212A, and 103,
ITU V.17, Group 3 T.4, T.30, and EIA TR-29
EIA TR-29 Class 2, CCITT V.17, Group 3, V.29, V27ter
AT standard instruction set and extended, V.250 basic
instruction set
V.42 (LAP-M or MNP 2 to 4)
V.42bis (throughput 4:1), MNP 5 (throughput 2:1)
LED data indicator
Audible signaling
Operating diagnostics
Adaptive cable test
Telecommunications approvals
Hardware settings
Green LED (OH), off the hook
Yellow LED (AA), automatic answer (automatic call
acceptance), flashes during selective acceptance of
calls
Yellow LED (FAX) fax mode active
Yellow LED (EC) error correction in V.42 mode, flashes
when data compression is active
Integrated piezo
Power on selftest, visualization via LEDs (controller,
SRAM, EEPROM, DSP)
Dial tone test, pulse dial ring test via additional function
in configuration software
TBR21, TBR15, TIA/EIA/IS-968
for Europe, USA, and Canada
4-way DIP for dial-up and permanent line operation
(under removable cover)