Remotely unlock local operation

With the lower right button on the second page of the control panel locally operating the temperature sensor can be
enabled.



1. Remember the address of the sensor module to

reinstate it later.

2. Set the address of the sensor module to ‘81’.

The cooling, comfort, day and night LEDs are
flashing to indicate learning mode for pushbuttons
that unlock local operation.

Remark:
When multiple sensor modules need to react to the
same pushbutton, remember their addresses and
set them also to ‘81’.


3. Select the second page of the control panel by

pressing the small pushbutton.


4. Press and hold the ‘Unlock’ pushbutton

(at least 1 second) until its indication LED starts
flashing.

Remark:
As long as the pushbutton is pressed, the LEDs on
the sensor module will be off. This to confirm that
the pushbutton is assigned.

5. Repeat step 4 in case other pushbuttons must

enable local operation of the sensor.

6. Reinstate the address of the sensor module(s) to

its (their) original value.


















ADDR = 81

 

 

Warm Vergrendel
Koel Ontgrendel

 

 

Heating Lock
Cooling Unlock