Time statistics, Minimum and maximum temperature, Differential thermostat – Velleman VMB1TS User Manual
Page 17: Factory settings

VMB1TS manual – edition 2
17
Time statistics
For every mode (comfort, day, night or anti-freeze) the time during which the heating or air-conditioning was one is
stored.
These statistics can be recalled or reset via the temperature controller (VMB1TC) or through the Velbus link software
via a PC connected to the Velbus PC interface (VMB1USB, VMB1RS of VMBRSUSB).
Minimum and maximum temperature
The sensor records the minimum and maximum temperature.
These values can be examined or reset via the temperature controller (VMB1TC) or through the Velbus link software
via a PC connected to the Velbus PC interface (VMB1USB, VMB1RS of VMBRSUSB).
Differential thermostat
Using two sensors a differential thermostat can be created. When the difference in temperature between both sensors
reaches a certain value, the relay channel can be activated.
To achieve this, the first sensors must know the address of the second one. The second sensor must than be linked
to a relay channel. The temperature difference value is set on the first sensor.
Factory settings
After receiving this module, following factory default settings are already stored into the sensor:
Description
Factory default
Zone number
No zone
Differential sensor address
None
Operating mode
Heating
Unjam heating valve
Disabled
Unjam heating valve circulation pump
Disabled
Desired comfort temperature for heating
22°C
Desired day temperature for heating
20°C
Desired night temperature for heating
15°C
Anti-freeze safeguard
5°C
Heating limit
30°C
Temperature difference (fast heating/cooling or differential thermostat)
3°C
Calibration factor
-2.5°C
Hysteresis
0.5°C
Desired comfort temperature for cooling
21°C
Desired day temperature for cooling
23°C
Desired night temperature for cooling
26°C
Lower limit cooling preset range
16°C
Upper limit cooling preset range
36°C
Low temperature alarm
3°C
High temperature alarm
30°C
Default duration temporary mode (sleep timer)
1 hour
Time interval for automatic transmission temperature
Disabled
Local control
Unlocked
Cycling protection delay
1 minute