Remotely set heating mode

With the upper left button on the second page of the control panel the temperature sensor is set in heating mode.


1. Remember the address of the sensor module to

reinstate it later.

2. Set the address of the sensor module to ‘B1’.

The heating LED flashes to indicate learning mode
for pushbuttons that place the module in heating
mode.

Remark:
When multiple sensor modules needs to react to
the same pushbutton, remember their addresses
and set them also to ‘B1’.


3. Select the second page of the control panel by

pressing the small pushbutton.

4. Press and hold the ‘Heating’ pushbutton

(at least 1 second) until its indication LED starts
flashing.

Remark:
As long as the pushbutton is pressed, the LEDs on
the sensor module will be off. This to confirm that
the pushbutton is assigned.

5. Repeat step 4 in case other pushbuttons must set

the sensor module in heating mode.

6. Reinstate the address of the sensor module(s) to

its (their) original value.















ADDR = B1

 

 

Heating Lock
Cooling Unlock

 

 

Heating Lock
Cooling Unlock