Ii - 6 error messages, Ii - 6 er ro r messag e s ii - 6 error messages – ACU-RITE 200S User Manual
Page 92
78
II
II - 6 Er
ro
r Messag
e
s
II - 6 Error Messages
The following table provides a complete list of error messages that
may be received from the 200S DRO.
An explanation of each error message is provided in the following
table.
Error
DRO Error Message
Explanation
1
Power was off. Press any key to
continue.
200S power was just cycled.
2
Contamination & Frequency Error:
Press C to clear error.
Contamination, and frequency errors occurred at corresponding encoder.
User intervention to monitor, and/or correct the encoder.
3
Contamination Error: Press C to
clear error.
Contamination error occurred at corresponding encoder. User intervention to
monitor, and/or correct the encoder.
4
Frequency error: Press C to clear
error.
Frequency error occurred at corresponding encoder. User intervention to
monitor, and/or correct the encoder.
5
Miscount error: Press C to clear
error.
Miscount error occurred at corresponding encoder. User intervention to
monitor, and/or correct the encoder.
6
Display Overflow error: Move
within display range.
The encoder is currently out of the display range specified by the user. Move
the encoder to within the display range, or modify the encoder display.
7
Error: The valid range for number of
holes is 1-99.
The number of holes defined for the current pattern is out of range. User must
adjust the number of holes.
8
Error: The radius must be greater
than 0.0.
The user defined radius must be greater than zero to define a circle.
9
Error: The spacing must be greater
than 0.0.
The spacing between holes in a pattern must be greater than zero to define a
pattern.
10
Error: The start and end points can
not be the same.
The start, and end points of the field must be unique to define a line.
11
Error: The distance from the center
is not equal to the radius.
The distance from the center value is invalid, and must be modified by the
user.
12
Error: The ARCCOS function can
only operate on values from - 1to 1.
Range error on the value to fetch the arccos of.