II - 5 Remote Switch Data Output
The remote switch (pendant or footswitch), or Ctrl B (sent over serial
interface), will transmit the currently displayed values in either Actual
Value or Distance-To-Go mode, whichever is currently visible.
Data output using external signals
Example 1: Linear axis with radius display X = + 41.29 mm
1
Coordinate axis
2
Equal sign
3
+/– sign
4
2 to 7 places before the decimal point
5
Decimal point
6
1 to 6 places after the decimal point
7
Unit: blank space for mm, “ for inches
8
Absolute display:
R for radius, D for diameter
Distance-to-go display:
r for radius, d for diameter
9
Carriage return
10
Blank line (Line Feed)
X
=
+
4 1
.
2 9
R
1
2
3
4
5
6
7
8
9
10