Measured value output, Near zero warning, Status bar settings – ACU-RITE 200S User Manual
Page 29
![background image](/manuals/248945/29/background.png)
200S
15
I - 2 Gener
a
l Oper
ations f
o
r 20
0S
Measured Value Output
With the measured value output feature, probe measurement values
can be sent over the serial port. Also output of the current display
positions is activated via a command (Ctrl B), sent to the 200S over the
serial port.
The Measured Value Output form is used to set data output during
probing operations.
Data Output Probing (Milling Only), may be set to either On, or Off.
When On, the measurement data is output when the probe
operation is completed.
Refer to chapter "II - 5 Remote Switch Data Output on page 73” for
information on the format of the output data.
Near Zero Warning
The Near Zero Warning form, is used to configure the bar graph. This
is shown below the axes’ display in Distance-To-Go mode. Each axis
has its own range.
8
Press the ON/OFF soft key to enable, or begin entering values using
the numeric keys. The current position box will begin moving when
the position is within range.
Status Bar Settings
The Status Bar is the segmented bar at the top of the screen which
displays current datum, tool, feed rate, job clock and page indicator.
8
Press the ON/OFF soft key for each setting you want to
see displayed.