beautypg.com

Accusys Acuta User Manual

Page 51

background image

Appendix A – FAQ


51

15.

What should I do when I see below error message on LCD?

Ö Condition 1

R A I D F a i l

C o d e : 0

Note: not enough number of function disks for a RAID to operate

Solution: Install all of 4 disks to conform to create a new RAID.

Ö Condition 2

R A I D F a i l

C o d e : 1 < x x x x >

Note:

Represents disk sequence is wrong, and the current sequence displayed within <>

Solution: Replace the sequence of disk as original.

Example:

<2134>: disk 2 and disk 1 sequence is reversed.

<13x4>: the original disk 3 is put into tray 2 and the original disk 2 is not plugged

or failed.

Ö Condition 3

R A I D F a i l

C o d e : 2

Note: The RAID has been failed but all of 4 disks exist. Since F/W Version 1.4 or
later.

Solution: To create a new RAID or you should call Accusys product support center
to try to save the data from system.

格式化: 項目符號及編號

格式化: 項目符號及編號

格式化: 項目符號及編號

刪除: I loaded four disks
and turned on the
subsystem to set up an
array but the display
shows “RAID fail” and
the alarm is sounding.
How do I solve the
problem?