beautypg.com

Accusys Acuta User Manual

Page 35

background image

Chapter 4 – Setting up an array

35

The upper disk status indicator and low disk activity indicator on each drive carrier indicate the
following:

Disk Status
Indicator

Disk Activity
Indicator

Controller Status

Alternating green
& amber

Flashing blue

ƒ RAID being initialized

Alternating green
& amber

Flashing blue

ƒ RAID being rebuilt

Solid green

Unlit

ƒ RAID initialization complete

Solid green

Unlit

ƒ RAID established / no activity

Solid green

Flashing blue

ƒ Data

being

accessed

Solid red

Unlit

ƒ Disk failure / disk not properly

installed

Solid amber

Unlit

ƒ Hot spare disk in R5+spare

mode

If a red disk status indicator shows, check to make sure the appropriate drive is:

z Locked

z Installed

correctly

z

Not faulty (if necessary, the drive should be replaced).

The alarm will sound in case of RAID failure. Press the Enter / Mute
button to the right of the display to silence the alarm.

Initialization of an array may take up to 15 minutes depending on the capacity of disks and the
RAID level selected.

The status of the controller and array is given by the LCD display. Press the scroll button to the
left of the display to scroll through information about the array. The following information is
available:

Ö RAID level and Capacity
Ö Disk

model

Ö Disk DMA mode and capacity
Ö Firmware Version
Ö Serial

Number

Ö Fan Status and Temperature Status