SIS-PMS-LAN PROGRAMMABLE SURGE

PROTECTOR WITH LAN INTERFACE

All brands and logos are registered trademarks of their respective owners

The new event time should be in the future

There can not be a duplicate entry

The total quantity of events can not exceed 16 per socket

The total quantity of events also depends on the total execution

period of the schedule

The interval between the present and the last entry can not exceed

180 days

Without loop the total execution period of the schedule can not

exceed 215 days

Loop period can not exceed 180 days

NOTE: The hardware schedule keeps running even when the device

is powered off. However it is recommended not to power off the device
for extended periods, because the built-in battery has a limited lifespan. If
the battery dies the schedule will be completely cleared. The total lifetime
of the battery is no less than 2 years if the device is powered off, and no
less than 5 years if the device is powered on.

6.2. Setting up software schedule

Using the Software schedule button available from the Settings

window (see section 5.2 above) you can create the software timer
schedule (see Figure #21 below).