beautypg.com

Table 1: capacity rating - cooling / electric heat, 1 sunline ultra cutaway (model dhg, Gas heating) – York D2HE/D2HG060 User Manual

Page 5: 1 capacity rating - cooling / electric heat

background image

036-21216-003-A-0204

Unitary Products Group

5

WALL THERMOSTAT - The units are designed to operate
with 24-volt electronic and electro-mechanical thermostats.

All units can operate with single stage heat / single stage cool
thermostats - with or without the economizer.

.

FIGURE 1 - SUNLINE ULTRA CUTAWAY (Model DHG gas heating)

L O W V O L T A G E R E L A Y B O A R D

A N D T E R M I N A L S T R I P

B E L T D R I V E

B L O W E R M O T O R

2 0 G A U G E A L U M I N I Z E D

S T E E L T U B U L A R H E A T

E X C H A N G E R

L O N G L A S T I N G

P O W D E R P A I N T F I N I S H

E L E C T R I C H E A T

A C C E S S O R Y

L O C A T I O N

( E l e c / E l e c U n i t s )

P O W E R V E N T E R M O T O R

W I T H P O S T P U R G E C Y C L E

H I G H E F F I C I E N C Y

C O M P R E S S O R S

F U L L P E R I M E T E R B A S E

R A I L S W I T H F O R K L I F T

S L O T S A N D L I F T I N G H O L E S

C O P P E R T U B E /

A L U M I N U M F I N

C O N D E N S I N G C O I L

K N O C K O U T F O R S I D E

G A S S U P P L Y E N T R Y

K N O C K O U T F O R B O T T O M

P O W E R E N T R Y

K N O C K O U T F O R B O T T O M

G A S S U P P L Y E N T R Y

T E R M I N A L B L O C K

( F o r S i n g l e P o i n t P o w e r

S u p p l y o n E l e c / E l e c U n i t s )

K N O C K O U T S F O R

S I D E P O W E R A N D

C O N T R O L E N T R Y

3 / 4 " P V C F E M A L E

C O N D E N S A T E D R A I N

B O T T O M R E T U R N A I R

D U C T O P E N I N G

S I D E R E T U R N A I R

D U C T O P E N I N G

O U T D O O R A I R O P E N I N G

F O R S L I D E - I N / P L U G - I N

I N T N E R A L E C O N O M I Z E R

E C O N O M I Z E R H O O D

E L E C T R I C A L D I S C O N N E C T

M O U N T I N G L O C A T I O N

( F i e l d I n s t a l l e d )

TABLE 1: CAPACITY RATING - COOLING / ELECTRIC HEAT

MODEL

ARI RATINGS

1

NOMINAL ELECTRIC HEAT CAPACITY

2

(kW)

COOLING CAPACITY

80 / 67-95°F

SOUND

RATING

3

(dBels)

MBH

SEER

4

EER

5

240V

480V

DHE036

42.5

12.25

11.10

86

5, 7, 10,

15 & 20

7, 10,

15 & 20

DHE048

46.5

13.20

11.40

87

DHE060

57.0

12.20

10.60

86

5, 7, 10,

15, 20 & 30

7, 10, 15,

20 & 30

1.

Certified in accordance with the Unitary Small Equipment certification program, which is
based on ARI Standard 210/240.

2.

Heaters are available as accessories - all with single point power supply.

3.

Rated in accordance with ARI Standard 270.

4.

SEER = Seasonal Energy Efficiency Ration - the total cooling output in BTU’s during a nor-
mal annual usage period for cooling divided by the total electric power input in watt-hours
during the same period.

5.

EER = Energy Efficiency Ration - the cooling capacity in Btu’s per hour (Btuh) divided by
the power input in watts at any given set of rating conditions, expressed in BTUH per watt
(BTUH/watt).