Results in a 2-byte response representing the version of the installed firmware.
The first byte represents major versions, and the second byte minor versions.
If no firmware is loaded, the printer will answer with 00h.
Results in an 6-byte response representing the serial number of the printer’s control board.
Results in a 1-byte response representing the control board revision. A minus sign indicates
that no revision has been made, while A indicates the first revision, and so on.
ESC ENQ 7
Firmware-version Enquiry
1B 05 07
Hex
27 5 7
decimal
Example •
Send
Read
<2><29>
That is, a response with the value <1><29> indicates version 2.41.
ESC ENQ 9
Control Board Serial-number Enquiry
1B 05 09
hex
27 5 9
decimal
Example •
Send
Read
00 00 02 02B 0C6 028 (hex), or 0 0 2 43 198 40 (dec)
ESC ENQ 10
Control Board Revision Enquiry
1B 05 0A
hex
27 5 10
decimal
Example •
Send
Read
n