Configuring the v.120 mode – ZyXEL Communications Omni TA128 User Manual
Page 64

52
support out-of-band signaling, network signals are transmitted
through the B channels. This reduces the bandwidth to 56Kbps.
When you are making a V.120 call, make sure that the
communication supports out-of-band signaling. If it does not
support out-of-band signaling, you will need to set your TA128 to
56K mode using the AT&E1 command (AT&E0 to set it back to
64k mode.) If your TA128 is on the receiving end, you can keep the
setting at AT&E0, 64k data mode. The TA128 will automatically
switch between the two speeds in answer mode.
Configuring the V.120 mode
To configure for a 56K V.120 call, type:
ATB20
TA128 responds:
OK
Type:
AT&E1
TA128 responds:
OK
Now you are ready to dial the phone number. If you need to save
the setting into non-volatile RAM, issue the commands:
Type:
AT&W0
3]
TA128 responds:
OK
Type:
ATZ0
0) [Profiles available: 0-3]
TA128 responds: