beautypg.com

ZyXEL Communications Omni TA128 User Manual

Page 152

background image

140

Command bit dec hex Function and description

Ref.

2

2

Discard POTS port 2 global
incoming call when port 1 is
busy (Sending RELEASE
COMPLETE).

2

0

0

POTS 1 call-waiting/multiple-
answer disabled.

*4

4

POTS 1 call-waiting/multiple-
answer enabled.

3

0

0

POTS 2 call-waiting/multiple-
answer disabled.

*8

8

POTS 2 call-waiting/multiple-
answer enabled.

4

*0

0

POTS port 1 is connected to a
telephone.

16

10

POTS port 1 is connected to a
fax/modem.

5

*0

0

POTS port 2 is connected to a
telephone.

32

20

POTS port 2 is connected to a
fax/modem.

7

*0

0

Sending RELEASE
COMPLETE with cause ‘user
busy’ for ATH 1.

S80=

bit dec hex Bit-mapped register:

+000

4

0 * 0

Do not send Low Layer
Compatibility information for
Phone 2 (TA128) or internal
fax/modem (2864I).

16

10

Send Low Layer Compatibility
for Phone 2 (TA128) or
internal fax/modem (2864I).