beautypg.com

Analyzing the captured data – ZyXEL Communications Omni TA128 User Manual

Page 121

background image

109

The following commands determine the kind of protocol data to be
captured by the EPA:

AT Command

Description

ATCDn
CD0

Disable the capture of D-channel protocols

CD1

Enable the capture of D-channel protocols
(default)

ATCBn
CB0

Disable the capture of B-channel protocols
(default)

CB1

Enable the capture of B-channel protocols

ATCCn
CC0

Disable the capture of DTE-DCE interface
protocols(default)

CC1

Enable the capture of DTE-DCE interface
protocols

The EPA starts to capture data when the command ATCT is issued.
This capturing process will continue until the command ATC$ is
issued. The EPA maintains 8 Kbytes RAM as a ring buffer. In
case the buffer is full, the earliest data captured will be overwritten
by the latest data.

Analyzing the Captured Data

To view the analyzed result, use the command ATC$. For your
convenience, the relevant AT commands are summarized as
follows:

Command

Description

ATCT

Clears buffer and starts the embedded protocol
analyzer. Captures data immediately and starts the
timer.