beautypg.com

Wayne-Dalton 8000 SERIES 46 User Manual

Page 27

background image

27

Please Do Not Return This Product To The Store. Contact your local Wayne-Dalton dealer. To find your local Wayne-Dalton dealer, refer to your

local yellow pages/business listings or go to the

Find a Dealer section online at www.wayne-dalton.com

Tools Needed:

Tools Needed:

INST

All

ATION

26

DISCONNECT

CABLE

S-hOOk

hOLE IN RIGhT

END BRACkET

NOTE: See

idrive

®

main installation and

owners manual for

idrive

®

parts.

Attach the loose disconnect cable
(located in opener hardware bag) to the
opener with the “S” hook. Close both
ends of the “S” hook to lock assembly
together with pliers.

Thread the disconnect cable (behind the
counterbalance cable) through the hole
in the right hand end bracket, and
remove all slack between opener and
right end bracket.

Attaching Disconnect Cables

Pliers

Mounting Disconnect

handle bracket

Pencil

Tape Measure

1/8” Drill Bit

7/16” Socket

Driver

Power Drill

CLOSE “S” hOOk

hOLE IN

END BRACkET

RIGhT SIDE Of

END BRACkET

6ft

NOTE: See

idrive

®

main installation and

owners manual for

idrive

®

parts.

Mark a location on the right jamb, 6
feet above the floor to mount the
disconnect handle bracket.

Drill 1/8” pilot holes for the lag screws.

Align top of the bracket with the mark.
fasten bracket to the jamb with
(2) 1/4” x 1-1/2" hex head lag screws.

(2) 1/4 x 1-1/2"

hEx hEAD LAG

SCREWS

DISCONNECT

hANDLE BRACkET