VistARad Configuration—Sending Sites
For sites that will be sending autorouted images:
The
MAG VISTARAD SITE PARAMETERS
File (#2006.69) needs to be edited.
A site’s
SITE CODE
(
IMAGING SITE PARAMETERS
File (#2006.1)) must be set to a
non-null value that will identify the sending site.
To set routing-related VistARad site parameters
1
Open a terminal window and log into the VistA Hospital Information System.
2
Access the VistARad System Options menu [MAGJ MAIN] and run the “E/E
VistARad Site Parameters” option [MAGJ VISTARAD SITE PARAMETERS].
3
Set the routing-related fields (shown in bold below) to YES.
Select MAG VISTARAD SITE PARAMETERS VISTARAD SITE NAME: DEMO
VISTARAD SITE NAME: DEMO//
ENABLE STATUS UPDATE?: YES//
RECENT EXAMS DAYS LIMIT: 9999//
UNREAD EXAMS DAYS LIMIT: 9999//
PREFETCH ACTIVE?: YES//
LIST ONLY EXAMS HAVING IMAGES?: NO//
ENABLE SERIES DISPLAY?: YES//
BACKGROUND COMPILE EXAM LISTS?: NO//
UNREAD BKGND COMPILE INTERVAL: 2//
RECENT BKGND COMPILE INTERVAL: 30//
REMOTE LIST ONLY REMOTE CACHE?: NO// YES
SITE SENDS TO REMOTE CACHE: NO// YES
PATIENT LIST LIMIT # YEARS: 10//
PATIENT LIST LIMIT # EXAMS: 15//
UNREAD LIST PRIORITY SEQ: S,U,P,R//
 These steps assume that other fields in
MAG VISTARAD SITE PARAMETERS
are
already set as desired. For information about other site parameters, refer to chapter
3 in the VistA Imaging Installation Guide.
4
Use FileMan to check the value of your site’s
SITE CODE
field (#2006.1,.09). The
value entered must not match any of the
CacheLocationID
values defined at
1
REMOTE LIST ONLY REMOTE CACHE?
This field is retained for backward compatibility. For
sites using the patch 32 VistARad client, this field, when set to YES, will show only the exams
that have been routed to their site. For sites using the patch 18 client, this setting is a filter that
can be set as desired by each user. For more information, refer to the VistARad Quick Start
Guide.
2
SITE SENDS TO REMOTE CACHE?
Setting this field to YES turns on extra processing that
is needed to manage routed exams properly. One of the results of setting this field to YES is the
addition of the RC column to VistARad’s exam lists. The RC column is described on page
59
.