Dicom gateway configuration, Image gateway configuration – Vista Imaging Vista Routing User Manual
Page 50

Configuring Routing
Routing User Guide
6
Set the following three prompts as desired for autorouting priors. Details follow.
AUTO-DISPLAY: YES//
VERSION LIMIT/AUTO-DISPLAY: 1//
DAYS LIMIT/AUTO-DISPLAY: 1800//
AUTO-DISPLAY?
The value of this field should be set to “YES” for entries that should cause
autorouting of prior studies
DAYS LIMIT/AUTO-DISPLAY
The value of this field should be set to an integer number. Studies that precede the
current image by more than this number of days will not be candidates for auto-
routed transmission. Only studies that are less than the number of specified days
will be included.
VERSION LIMIT/AUTO-DISPLAY
The value of this field should be set to an integer number. This number indicates
the maximum number of prior studies that will be auto-routed for the current
image.
Note: The names of fields will be changed in a future patch.
7
Select additional fields to edit, or exit FileMan.
DICOM Gateway Configuration
A site that is the source of auto-routed images will need to set the configuration file for
all Image and Routing Gateways as described in the following sections.
 No configuration changes are needed for Text Gateways in a routing system.
Image Gateway Configuration
Image Gateways at a site using autorouting will need to have their configuration file set
as described below.
 The following steps cover only routing-related configuration parameters. For
information about other configuration parameters, refer to the DICOM Gateway
Installation Guide.
To configure Image Gateways
1
Open a terminal window and log into the DICOM Gateway software.
2
Enter
4
to select “System Maintenance” from the DICOM Gateway Menu
[
MAGDMENU
].
VistA Imaging V. 3.0, Patch 18
April 2006
42