Edit Frequency

Set Modulation

Auto

FM

NFM

Set Attenuation

On

Off

Set Tone

Edit Tone A

Edit Tone B

Set Delay Time

1-5 sec

Infinite

Off

Set Alert

Alert 1 9

Off

Notes:

[HOLD/RESUME]

Enter the desired frequency that the scanner should

monitor for the tone-out.

— Set the modulation type for the paging signal. Next

choose the modulation setting:

— The scanner uses the default modulation for the frequency band. If

the default modulation is AM, WFM, or FMB, the modulation operates as

FM.

— The scanner uses FM for the frequency band. This is the default

setting.

— The scanner uses NFM modulation.

— Turn the Scroll Control to select

or

.

— Sets the audio tone frequency for the page. Then choose the Tone

setting.

— Set the audio frequency for Tone A

— Set the audio frequency for Tone B\

For two-tone pages, enter a value for A and B.
For one-tone pages using short tones of less than 3.75 seconds, enter the

tone value for A, and 0 (zero) for B.
For long-tone pages, such as group pages of more than 3.75 seconds, enter

0 (zero) for A and the tone value for B.

— Sets the time the scanner remains in monitor mode after the

scanner receives a page and the carrier drops.

— the scanner resumes standby mode after the carrier drops and

the selected time expires.

— you must press

after a page to resume

standby mode.

— the scanner resumes standby as soon as the carrier drops after a

page.

— Sets the alert the scanner uses when it receives an alert.

- — scroll to select the alert tone pattern, The scanner sounds

each alert as you scroll to its numbered value.

— the scanner does not sound an alert.