APPENDIX 1 MESSAGES AND LEDS

ENGLISH VERSION EO1-33048

APPENDIX 1 MESSAGES AND LEDS

EA1- 2

LED Indication

No.

LCD Message

ONLINE ERROR

Printer Status

Restoration by

RESTART key

(Yes/No)

Acceptance of

Status Request

Reset Command

(Yes/No)

21

SYSTEM ERROR

z



When the following abnormal operations are
performed, a system error occurs:

(a) Command fetch from an odd address
(b) Access to word data at an odd address
(c) Access to long-word data at an odd

address

(d) Access to the area of 80000000H to

FFFFFFFFH in the logic space in user
mode.

(e) An undefined instruction in an area

other than a delay slot was decoded.

(f) An undefined instruction in a delay slot

was decoded.

(g) An instruction to rewrite a delay slot

was decoded.

No No

22

100BASE LAN
INITIALIZING…

z

z 100 Base LAN Board is being initialised.

-----

-----

23

DHCP CLIENT
INITIALIZING…

z

z The DHCP client is being initialized.

*When the DHCP function is enabled.

----- -----

24

RFID WRITE ERROR

z



The printer did not succeed in writing data
onto an RFID tag after having retried for a
specified times.

Yes Yes

25

RFID ERROR

z

 The printer cannot communicate with the

RFID module.

Yes Yes

NOTE: When an error message listed above appears on the LCD message display, please refer to Section 5