beautypg.com

11 threshold setting (cont.) – Toshiba B-SA4TP SERIES User Manual

Page 77

background image

2.PRINTER SETUP

ENGLISH VERSION EO1-33048

2.11 Threshold Setting

E2-64

2.11 Threshold Setting

(Cont.)


















„ Storing a “No Media Level” Voltage

The following is how to set a “No media level” voltage that is used to
detect a paper end.
If a “NO PAPER” is displayed even if the media has not run out yet, this
voltage needs to be set again.

(1) Remove any media from the Black Mark Sensor/Feed Gap Sensor.


(2) A real-time voltages being detected by the Black Mark Sensor and

Feed Gap Sensor are displayed.






(3) Press and hold the [RESTART] or [FEED] key for about 3 seconds.


(4) When storing a “no media level” voltage is completed, an asterisk

“*”is displayed on the right side of a voltage. Press the [PAUSE] key.


(5) The message returns to “<5>SENSOR ADJ.”.



„ Manual Threshold Setting

Then, set the calculated threshold voltage in the Parameter Fine
Adjustment mode.





(1)

While “<5>SENSOR ADJ.” is displayed, press the [FEED] or
[RESTART] key until “<3>ADJUST SET” is displayed.













(2)Press the [PAUSE] key to enter the Parameter Fine Adjustment Mode.

<5>SENSOR ADJ.
[PE]R0.1V T4.8V

<5>SENSOR ADJ.
[PE]R0.1VT4.8V*

<5>SENSOR ADJ.

Feed Gap Sensor

Black Mark Sensor

R

<5>SENSOR ADJ.

F

<3>ADJUST SET

P