2.PRINTER SETUP

ENGLISH VERSION EO1-33048

2.11 Threshold Setting

E2-65

2.11 Threshold Setting

(Cont.)












The Parameter Fine Adjustment Mode contains sub menus for adjusting a
print start position, cut/strip position, print tone, etc., and setting a
threshold. For details, refer to Section 2.10 Print Position and Print
Tone Fine Adjustment
.
Each time the [PAUSE] key is pressed, the sub menus are displayed
sequentially.


(3) While “<3>ADJUST SET.” is displayed, press the [PAUSE] key

until the target sensor type is displayed.











(4) Set a threshold voltage (calculated in Sensor Adjustment Menu) by

using the [FEED] or [RESTART] key, as shown below.

Threshold voltage = Midpoint between voltage at a print area and

voltage at a gap/black mark



















(5) After choosing a threshold voltage, press the [PAUSE] key.

(6) To check for a proper operation, issue the pre-printed media in online.

If an error still occurs even after a manual threshold setting, change
the threshold voltage a little, and retry.



NOTE:

Pressing the [FEED] key one time
causes a –0.1V change, up to 0.0V.

Pressing the [RESTART] key one
time causes a +0.1V change, up to
+4.0V.

<3>ADJUST SET
THRESHOLD1.4V

<3>ADJUST SET
THRESHOLD1.0V

Black Mark Sensor

Feed Gap Sensor

[RESTART]

[FEED]

THRESHOLD4.0V

THRESHOLD3.9V

THRESHOLD3.8V

THRESHOLD0.1V

THRESHOLD0.0V

Black Mark Sensor

THRESHOLD4.0V

THRESHOLD3.9V

THRESHOLD3.8V

THRESHOLD0.1V

THRESHOLD0.0V

Feed Gap Sensor

[PAUSE]