11 threshold setting (cont.) – Toshiba B-SA4TP SERIES User Manual
Page 78

2.PRINTER SETUP
ENGLISH VERSION EO1-33048
2.11 Threshold Setting
E2-65
2.11 Threshold Setting
(Cont.)
The Parameter Fine Adjustment Mode contains sub menus for adjusting a
print start position, cut/strip position, print tone, etc., and setting a
threshold. For details, refer to Section 2.10 Print Position and Print
Tone Fine Adjustment.
Each time the [PAUSE] key is pressed, the sub menus are displayed
sequentially.
(3) While “<3>ADJUST SET.” is displayed, press the [PAUSE] key
until the target sensor type is displayed.
(4) Set a threshold voltage (calculated in Sensor Adjustment Menu) by
using the [FEED] or [RESTART] key, as shown below.
Threshold voltage = Midpoint between voltage at a print area and
voltage at a gap/black mark
(5) After choosing a threshold voltage, press the [PAUSE] key.
(6) To check for a proper operation, issue the pre-printed media in online.
If an error still occurs even after a manual threshold setting, change
the threshold voltage a little, and retry.
NOTE:
Pressing the [FEED] key one time
causes a –0.1V change, up to 0.0V.
Pressing the [RESTART] key one
time causes a +0.1V change, up to
+4.0V.
<3>ADJUST SET
THRESHOLD
<3>ADJUST SET
THRESHOLD
Black Mark Sensor
Feed Gap Sensor
[RESTART]
[FEED]
THRESHOLD
THRESHOLD
THRESHOLD
THRESHOLD
THRESHOLD
Black Mark Sensor
THRESHOLD
THRESHOLD
THRESHOLD
THRESHOLD
THRESHOLD
Feed Gap Sensor
[PAUSE]