Built-In Installation (Figure 3)
TurboChef ovens are designed to be installed on a
countertop or table. They are not intended for
built-in or enclosed installation.
“Built-in or enclosed installation” is defined as
installing an oven in any structure that surrounds
the oven by five sides (i.e., top/rear/side panels and
base).
If installation must be “built in,” the operator
must ensure the following:
Minimum of 300 cfm (8.5 cmm) of supplement
flow within the cabinet.
Minimum clearances of 2′′ (51 mm) to every
surface.
In addition, the operator will be responsible for
compensating any extra time required to service
the product due to removing the product for
serviceability.
2.0" (51mm)
2.0" (51mm)
2.0" (51mm)
1: Must be included by contractor
4.0" (102 mm)
300 CFM (8.5 CMM)
Discharge to Ambient
Fan
2.0" (51mm)
Unobstructed
Airflow
Unobstructed
Airflow
Notes:
F I G U R E
4: Installation Near Open Heat Source
F I G U R E
3: Built-in Installation
5
THEORY OF OPERATION, SPECIFICATIONS, AND INSTALLATION