Omron NT-series Programmable Terminal V022-E3-1 User Manual
Page 146
3
Section 4-5
Orientation and incremental direction
The orientation and incremental direction of the bar graph can be selected from
those mentioned below.
↑
(up):
The bar graph increments upward in the vertical orientation.
↓
(down):The bar graph increments downward in the vertical orientation.
←
(left): The bar graph increments to the left in the horizontal orientation.
→
(right): The bar graph increments to the right in the horizontal orientation.
Direction:
→
Direction:
↑
Graph frame
Select whether or not the graph frame (boundary line of a graph display area)
which indicates the effective display range is displayed.
←
This frame is not displayed if
“Graph frame: No” has been set.
Setting the 100 % value and % display
Set a value which corresponds to 100 % for the “100 % value”. The available
value range is “0 to 99999999” (max. eight digits). For the “% display”, whether
or not the proportion (percentage) of the reference numeral memory table value
to the “100 % value” is displayed in a numeral can be selected. The display value
is calculated as follows:
“% display” value = Numeral memory table value
“100 % value” x 100
For the font and attributes used for the numeral display, refer to “Numerals which
can be displayed” (page 130).
Sign display and display method
Select whether or not the bar graph which indicates a value below 0 % is dis-
played.