beautypg.com

System exclusive message, Universal non-realtime system exclusive, V-link message – Roland PCR-80 User Manual

Page 176: Data set 1 dt1 (12h)

background image

176

MIDI implementation

System exclusive message

The PCR-30/50/80 is able to transmit the following exclusive messages: exclusive
messages assigned to the controllers, Identity Reply, V-LINK messages, and Bulk
Dump.

Universal non-realtime system exclusive

Identity reply

This message will be transmitted when an Identity Request message is received.

Status

Data byte

Status

F0H

7EH,10H,06H,02H,41H,62H,01H,

F7H

00H,00H,00H,01H,00H,00H

Byte

Explanation

F0H

Exclusive status

7EH

ID number (Universal non-realtime message)

10H

Device ID (For the PCR-30/50/80, fixed at 10H)

06H

Sub ID #1 (General Information)

02H

Sub ID #1 (Identity Reply)

41H

ID number (Roland)

62H 01H

Device family code

00H 00H

Device family number code

00H 01H

Software revision level

00H 00H

:

F7H

EOX (End of Exclusive)

V-LINK message

V-LINK ON

Transmitted when entering V-LINK mode.

Status

Data byte

Status

F0H

41H,10H,00H,51H,12H,

F7H

10H,00H,00H,01H,0FH,0FH,51H

Byte

Explanation

F0H

Exclusive status

41H

ID number (Roland)

10H

Device ID (For the PCR-30/50/80, fixed at 10H)

00H 51H

Model ID (V-LINK)

12H

Command ID (DT1)

10H 00H 00H

Address

01H

V-LINK ON

0FH

Clip Control Rx. MIDI Ch. (16ch)

0FH

Color Control Rx. MIDI Ch. (16ch)

51H

Checksum

F7H

EOX (End of Exclusive)

V-LINK OFF

Transmitted when exiting V-LINK mode.

Status

Data byte

Status

F0H

41H,10H,00H,51H,12H,

F7H

10H,00H,00H,00H,70H

Byte

Explanation

F0H

Exclusive status

41H

ID number (Roland)

10H

Device ID (For the PCR-30/50/80, fixed at 10H)

00H 51H

Model ID (V-LINK)

12H

Command ID (DT1)

10H 00H 00H

Address

00H

V-LINK OFF

51H

Checksum

F7H

EOX (End of Exclusive)

Sender Model Name

Transmitted when entering V-LINK mode.
Status

Data byte

Status

F0H

41H,10H,00H,51H,12H,

F7H

10H,71H,00H,45H,44H,49H,52H,4FH,4CH,
20H,50H,43H,52H,00H,3BH

Byte

Explanation

F0H

Exclusive status

41H

ID number (Roland)

10H

Device ID (For the PCR-30/50/80, fixed at 10H)

00H 51H

Model ID (V-LINK)

12H

Command ID (DT1)

aaH

Address

10H 71H 00H

Data

45H 44H 49H

Model name (EDIROL PCR)

52H 4FH 4CH

:

20H 50H 43H

:

52H 00H

:

3BH

Checksum

F7H

EOX (End of Exclusive)

Data Set 1 DT1 (12H)

Transmitted when you execute Bulk TX in the Bulk mode.
Status

Data byte

Status

F0H

41H, 10H, 00H, 62H, 12H,
aaH, ddH, ...eeH, sum

F7H

Byte

Explanation

F0H

Exclusive status

41H

ID number (Roland)

10H

Device ID

00H

Model ID #1 (PCR-30/50/80)

62H

Model ID #1 (PCR-30/50/80)

12H

Command ID (RQ1)

aaH

Address

ddH

Data

:
:
:
eeH

Data

sum

Checksum

F7H

EOX (End of Exclusive)

*

The amount of data that can be transmitted at once is fixed for each type of data.
Data that does not have the specified starting address and data size will not be
received. Refer to the explanation in 3. Bulk Dump.

*

There must be an interval of at least 40 ms between each exclusive message that
is sent.

*

Also, you must leave an interval of at least 500 ms after transmitting one set of
bulk dump data.

This manual is related to the following products: