System exclusive message, Universal non-realtime system exclusive, V-link message – Roland PCR-80 User Manual
Page 176: Data set 1 dt1 (12h)
176
MIDI implementation
■
System exclusive message
The PCR-30/50/80 is able to transmit the following exclusive messages: exclusive
messages assigned to the controllers, Identity Reply, V-LINK messages, and Bulk
Dump.
●
Universal non-realtime system exclusive
❍
Identity reply
This message will be transmitted when an Identity Request message is received.
Status
Data byte
Status
F0H
7EH,10H,06H,02H,41H,62H,01H,
F7H
00H,00H,00H,01H,00H,00H
Byte
Explanation
F0H
Exclusive status
7EH
ID number (Universal non-realtime message)
10H
Device ID (For the PCR-30/50/80, fixed at 10H)
06H
Sub ID #1 (General Information)
02H
Sub ID #1 (Identity Reply)
41H
ID number (Roland)
62H 01H
Device family code
00H 00H
Device family number code
00H 01H
Software revision level
00H 00H
:
F7H
EOX (End of Exclusive)
●
V-LINK message
❍
V-LINK ON
Transmitted when entering V-LINK mode.
Status
Data byte
Status
F0H
41H,10H,00H,51H,12H,
F7H
10H,00H,00H,01H,0FH,0FH,51H
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
10H
Device ID (For the PCR-30/50/80, fixed at 10H)
00H 51H
Model ID (V-LINK)
12H
Command ID (DT1)
10H 00H 00H
Address
01H
V-LINK ON
0FH
Clip Control Rx. MIDI Ch. (16ch)
0FH
Color Control Rx. MIDI Ch. (16ch)
51H
Checksum
F7H
EOX (End of Exclusive)
❍
V-LINK OFF
Transmitted when exiting V-LINK mode.
Status
Data byte
Status
F0H
41H,10H,00H,51H,12H,
F7H
10H,00H,00H,00H,70H
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
10H
Device ID (For the PCR-30/50/80, fixed at 10H)
00H 51H
Model ID (V-LINK)
12H
Command ID (DT1)
10H 00H 00H
Address
00H
V-LINK OFF
51H
Checksum
F7H
EOX (End of Exclusive)
❍
Sender Model Name
Transmitted when entering V-LINK mode.
Status
Data byte
Status
F0H
41H,10H,00H,51H,12H,
F7H
10H,71H,00H,45H,44H,49H,52H,4FH,4CH,
20H,50H,43H,52H,00H,3BH
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
10H
Device ID (For the PCR-30/50/80, fixed at 10H)
00H 51H
Model ID (V-LINK)
12H
Command ID (DT1)
aaH
Address
10H 71H 00H
Data
45H 44H 49H
Model name (EDIROL PCR)
52H 4FH 4CH
:
20H 50H 43H
:
52H 00H
:
3BH
Checksum
F7H
EOX (End of Exclusive)
●
Data Set 1 DT1 (12H)
Transmitted when you execute Bulk TX in the Bulk mode.
Status
Data byte
Status
F0H
41H, 10H, 00H, 62H, 12H,
aaH, ddH, ...eeH, sum
F7H
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
10H
Device ID
00H
Model ID #1 (PCR-30/50/80)
62H
Model ID #1 (PCR-30/50/80)
12H
Command ID (RQ1)
aaH
Address
ddH
Data
:
:
:
eeH
Data
sum
Checksum
F7H
EOX (End of Exclusive)
*
The amount of data that can be transmitted at once is fixed for each type of data.
Data that does not have the specified starting address and data size will not be
received. Refer to the explanation in 3. Bulk Dump.
*
There must be an interval of at least 40 ms between each exclusive message that
is sent.
*
Also, you must leave an interval of at least 500 ms after transmitting one set of
bulk dump data.